Keysight34461A#

class Keysight34461A(
visa_resource: str | VisaConfig,
)[source]#

Bases: DMMDriverBase

Keysight 34461A Truevolt DMM.

Methods

close

Close the underlying transport.

measure_ac_current

Trigger an AC-current measurement and return the value (amperes RMS, vendor-dependent).

measure_ac_voltage

Trigger an AC-voltage measurement and return the value (volts RMS, vendor-dependent).

measure_dc_current

Trigger a DC-current measurement and return the value (amperes).

measure_dc_voltage

Trigger a DC-voltage measurement and return the value (volts).

measure_four_wire_resistance

Trigger a 4-wire-resistance measurement and return the value (ohms).

measure_resistance

Trigger a 2-wire-resistance measurement and return the value (ohms).

open

Open transport and clear status/error queue.

set_ac_current_nplc

Unsupported — AC functions integrate via filter bandwidth (CURR:AC:BAND), not NPLC.

set_ac_current_range

Set manual AC-current range to value amperes; None selects auto-range.

set_ac_voltage_nplc

Unsupported — AC functions integrate via filter bandwidth (VOLT:AC:BAND), not NPLC.

set_ac_voltage_range

Set manual AC-voltage range to value volts; None selects auto-range.

set_aperture_seconds

Set integration time directly in seconds.

set_dc_current_nplc

Set DC-current integration time to nplc power-line cycles.

set_dc_current_range

Set manual DC-current range to value amperes; None selects auto-range.

set_dc_voltage_nplc

Set DC-voltage integration time to nplc power-line cycles.

set_dc_voltage_range

Set manual DC-voltage range to value volts; None selects auto-range.

set_digits

Unsupported — Truevolt SCPI has no digits command; use set_aperture_nplc for resolution.

set_four_wire_resistance_nplc

Set 4-wire-resistance integration time to nplc power-line cycles.

set_four_wire_resistance_range

Set manual 4-wire-resistance range to value ohms; None selects auto-range.

set_measurement_function

Select the function with FUNC; per-function range/NPLC settings are retained across switches.

set_two_wire_resistance_nplc

Set 2-wire-resistance integration time to nplc power-line cycles.

set_two_wire_resistance_range

Set manual 2-wire-resistance range to value ohms; None selects auto-range.

open() → None[source]#

Open transport and clear status/error queue. Truevolt has no SYST:REM; remote is automatic.

close() → None[source]#

Close the underlying transport. Idempotent.

set_measurement_function(
function: MeasurementFunction,
) → None[source]#

Select the function with FUNC; per-function range/NPLC settings are retained across switches.

set_digits(n: int) → None[source]#

Unsupported — Truevolt SCPI has no digits command; use set_aperture_nplc for resolution.

set_dc_voltage_range(value: float | None) → None[source]#

Set manual DC-voltage range to value volts; None selects auto-range.

set_ac_voltage_range(value: float | None) → None[source]#

Set manual AC-voltage range to value volts; None selects auto-range.

set_dc_current_range(value: float | None) → None[source]#

Set manual DC-current range to value amperes; None selects auto-range.

set_ac_current_range(value: float | None) → None[source]#

Set manual AC-current range to value amperes; None selects auto-range.

set_two_wire_resistance_range(
value: float | None,
) → None[source]#

Set manual 2-wire-resistance range to value ohms; None selects auto-range.

set_four_wire_resistance_range(
value: float | None,
) → None[source]#

Set manual 4-wire-resistance range to value ohms; None selects auto-range.

set_dc_voltage_nplc(nplc: float) → None[source]#

Set DC-voltage integration time to nplc power-line cycles.

set_dc_current_nplc(nplc: float) → None[source]#

Set DC-current integration time to nplc power-line cycles.

set_two_wire_resistance_nplc(nplc: float) → None[source]#

Set 2-wire-resistance integration time to nplc power-line cycles.

set_four_wire_resistance_nplc(nplc: float) → None[source]#

Set 4-wire-resistance integration time to nplc power-line cycles.

set_ac_voltage_nplc(nplc: float) → None[source]#

Unsupported — AC functions integrate via filter bandwidth (VOLT:AC:BAND), not NPLC.

set_ac_current_nplc(nplc: float) → None[source]#

Unsupported — AC functions integrate via filter bandwidth (CURR:AC:BAND), not NPLC.

measure_dc_voltage() → float[source]#

Trigger a DC-voltage measurement and return the value (volts).

measure_ac_voltage() → float[source]#

Trigger an AC-voltage measurement and return the value (volts RMS, vendor-dependent).

measure_dc_current() → float[source]#

Trigger a DC-current measurement and return the value (amperes).

measure_ac_current() → float[source]#

Trigger an AC-current measurement and return the value (amperes RMS, vendor-dependent).

measure_resistance() → float[source]#

Trigger a 2-wire-resistance measurement and return the value (ohms).

measure_four_wire_resistance() → float[source]#

Trigger a 4-wire-resistance measurement and return the value (ohms).

Default raises NotImplementedError; override on drivers whose instrument has dedicated sense leads (e.g. Agilent 34401A).

set_aperture_seconds(seconds: float) → None#

Set integration time directly in seconds.

Default raises NotImplementedError. Mutually exclusive with set_aperture_nplc on a given driver — vendors typically expose one or the other.