configure_ai_thermocouple_channel()#

LabJackTSeriesDriver.configure_ai_thermocouple_channel(
channel: AnalogThermocoupleChannel,
)[source]#

Configure a thermocouple ai channel; volts convert to temperature in the channel’s unit on read.

range_min/range_max are ignored: the ADC range is fixed per model (T7 0.1 V, T8 0.075 V, T4 none).