> ## Documentation Index
> Fetch the complete documentation index at: https://instro.nominal.io/llms.txt
> Use this file to discover all available pages before exploring further.

# Overview

> A Python library/framework for interfacing with hardware

`instro` is a Python library with the following objectives:

1. Accelerate the authoring of tests which rely on hardware instruments.
2. Provide abstractions that allow code reuse across various instrument models, so you can swap vendors without rewriting your test.
3. Define entry points for creating instrument interfaces and drivers that integrate with the library.
4. When you want to capture the data, offer low-code publishing to a file, a custom destination, or Nominal tools like Connect and Core.

It is a Python forward framework that should be accessible to engineers new to Python but
also extensible and useable by engineers who are Python savvy.

# Problem Space: Before and After

## Before: a different SDK for every vendor

Here's what's required to read analog data from two different DAQ vendors using their native SDKs. Each device has its own API, configuration sequence, and data-handling quirks, and the acquisition logic is tangled together with the code that ships the samples somewhere.

<AccordionGroup>
  <Accordion title="LabJack T-Series Devices">
    ```python theme={null}
    import time
    from labjack import ljm
    import nominal as nm

    DATASET_RID = "<your dateset rid>"

    # Initial Nominal Config
    client = NominalClient.from_profile("default")
    dataset = client.get_dataset(DATASET_RID)

    # Set up labjack
    aScanList = ljm.namesToAddresses(len(["AIN0", "AIN1"]), ["AIN0", "AIN1"])[0]
    handle = ljm.openS("ANY", "ANY", "ANY")
    info = ljm.getHandleInfo(handle)
    deviceType = info[0]
    if deviceType == ljm.constants.dtT4:
        aNames = ["STREAM_SETTLING_US", "STREAM_RESOLUTION_INDEX"]
        aValues = [0, 0]
    else:
        ljm.eWriteName(handle, "STREAM_TRIGGER_INDEX", 0)
        ljm.eWriteName(handle, "STREAM_CLOCK_SOURCE", 0)
        aNames = ["AIN0_RANGE", "AIN1_RANGE", "STREAM_RESOLUTION_INDEX"]
        aValues = [10.0, 10.0, 0]
        if deviceType == ljm.constants.dtT7:
            aNames.extend(
                ["AIN0_NEGATIVE_CH", "STREAM_SETTLING_US", "AIN1_NEGATIVE_CH"]
            )
            aValues.extend([199, 0, 199])
    numFrames = len(aNames)
    ljm.eWriteNames(handle, numFrames, aNames, aValues)

    # Start the labjack. Read 500 samples 10 times
    ljm.eStreamStart(handle, 500, len(aScanList), aScanList, 5000)
    with dataset.get_write_stream() as core_stream:
        for _ in range(10):
            # Read from Labjack
            readings = ljm.eStreamRead(handle)
            samples = readings[0]

            # Arrange data and send to Nominal Core
            timestamp = time.time()
            samples_per_channel = int(len(samples) / len(aScanListNames))
            dt = 1/5000
            t0 = timestamp - dt * len(samples_per_channel)
            for i, channel in enumerate(aScanListNames):
                core_stream.enqueue_batch(
                    channel_name = channel,
                    timestamps = [t0 + j * dt for j in range(samples_per_channel)],
                    values = [samples[j * len(aScanListNames) : (i + 1) * len(aScanListNames)] for j in range(samples_per_channel)][i],
                )

    ljm.eStreamStop(handle)
    ```
  </Accordion>

  <Accordion title="NI DAQ Devices">
    ```python theme={null}
    import nidaqmx
    from nidaqmx.constants import AcquisitionType
    import nominal as nm

    DATASET_RID = "<your dateset rid>"

    # Initial Nominal Config
    client = NominalClient.from_profile("default")
    dataset = client.get_dataset(DATASET_RID)

    with nidaqmx.Task() as task:
        task.ai_channels.add_ai_voltage_chan("Dev1/ai0:1")
        task.timing.cfg_samp_clk_timing(5000.0, sample_mode=AcquisitionType.CONTINUOUS)
        task.start()

        with dataset.get_write_stream() as core_stream:
            for _ in range(10):
                # Read from NI DAQ
                data = task.read(number_of_samples_per_channel=500)

                # Arrange data and send to Nominal Core
                timestamp = time.time()
                t0 = timestamp - 1/5000 * len(data[0])
                for i, ch_data in enumerate(data):
                    core_stream.enqueue(
                        channel_name = task.channel_names[i],
                        timestamps = [t0 + j * 1/5000 for j in range(len(ch_data))],
                        values = ch_data
                    )
        task.stop()
    ```
  </Accordion>
</AccordionGroup>

## After: one API across vendors

Here's the same workflow using `instro`'s `InstroDAQ`. The acquisition code is identical across vendors: change the driver and the rest stays the same. Capturing the data is one optional line (`add_publisher(...)`); drop it and the same script just reads into your process.

```python theme={null}
from instro.daq.drivers.labjack import LabJackTSeriesDriver
from instro.daq import InstroDAQ
from instro.daq.types import Direction
from instro.lib.publishers import NominalCorePublisher

DATASET_RID = "<your dataset rid>"

# Swap in NIDAQDriver/MCCDriver/Keysight34980A to target a different vendor.
daq = InstroDAQ(
    name="myDAQ",
    driver=LabJackTSeriesDriver(device_id="<your_device_id>"),
)
daq.add_publisher(NominalCorePublisher(dataset_rid=DATASET_RID))

daq.open()

daq.configure_analog_channel(
    direction=Direction.INPUT, physical_channel="AIN0", alias="ch_0", range_min=-10, range_max=10
)
daq.configure_analog_channel(
    direction=Direction.INPUT, physical_channel="AIN1", alias="ch_1", range_min=-10, range_max=10
)
daq.configure_ai_sample_rate(sample_rate=5000, samples_per_channel=500)

# Start the acquisition and launch a background daemon that fetches from the DAQ buffer
daq.start()

for _ in range(10):
    time.sleep(0.5)

daq.stop()
daq.close()
```

# Key Concepts of instro

* **Code to an interface**, not the specific instrument in use.
* **Configurable background daemons** read and expose measurements to your script.
* **Optional data publishing** to a file, a custom destination, or Nominal Core and Nominal Connect, by way of a customizable `Publisher` interface. Attach one when you want to capture data; skip it and `instro` is just an instrument-control library. Each attached publisher is owned by that instrument and closes with it.

## Two ways to get data

You can get measurements into your script in two ways. If a publisher is attached, **both options publish data** whenever a measurement is produced. The difference is who triggers the reads and how often.

|              | Background acquisition                                                                                                                                         | On-demand acquisition                                                                                                                                                                      |
| ------------ | -------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| **How**      | Call `start()`. A background daemon reads from the instrument at a fixed, configurable rate. Pull the latest N values with `get_channel()` when you need them. | Skip `start()`. Call read methods (`read_analog()`, `get_voltage()`, …) only when you want a measurement. Each call reads the device, and publishes the result if a publisher is attached. |
| **Best for** | Apps where data should always be available and publishing.                                                                                                     | Apps that need measurements only at specific times; lower system and bus load. DMMs are a good example.                                                                                    |

<Note>
  **Recommendation**

  Use the **background daemon pattern** for most workflows. Data is always available and publishing, and it often simplifies application code, especially for buffered acquisitions from a DAQ where you'd need to manage servicing a buffer yourself.

  Depending on your application, you may never need to call `get_channel()`, but the background daemon will always publish measurements for later analysis in tools like Nominal Core.
</Note>

Instrument-specific pages (e.g. [InstroDAQ](/instrumentation/daq)) describe the exact methods and timing options for each type.

# High Level Architecture

1. **Instrument Types / HALs**: Distinct classes for each type of instrument (e.g., DAQ, PSU, ELoad, I2C), each providing an opinionated and unified usage model. This design exposes a tailored interface that reflects typical usage patterns, making common workflows consistent across different vendors and models.
2. **Drivers**: Vendor- or model-specific drivers that handle low-level communication intricacies. HALs rely on these drivers to implement vendor- or model-specific details within the context of their higher level usage model.
3. **Publishers**: Components responsible for recording or transmitting instrument data and commands. For example, streaming measurement data to a dataset. Instruments own attached publishers and close them during teardown.

<img src="https://mintcdn.com/nominal/MmSUOGQpL-nFCwJN/images/diagram_architecture.png?fit=max&auto=format&n=MmSUOGQpL-nFCwJN&q=85&s=ce0fdf905221202fe016163f2716ca7b" width="2426" height="1254" data-path="images/diagram_architecture.png" />

<Note>
  **Publishers**

  Data is published as a direct result of an instrument method being called.

  For example, when you call `InstroPSU.get_voltage()`, this not only queries the instrument for the voltage but also causes all attached Publishers to publish the measurement response automatically.

  This makes it easy to ensure measurements and state changes are consistently recorded or streamed without explicitly managing yourself.

  Attach a publisher instance to one instrument. Use `SharedPublisher` when multiple instruments need to publish to the same underlying destination.
</Note>

### Instrument Types

These are the instrument types available out of the box. The [SDK reference](https://nominal-io.github.io/instro/instruments/) documents the full API for each type, including the vendor driver classes.

* `InstroPSU`: programmable power supply units
* `InstroDAQ`: data acquisition systems
* `InstroELoad`: electronic loads
* `InstroDMM`: digital multimeters
* `InstroScope`: oscilloscopes
* `I2CInterface`: I2C bus communication devices
* `ModbusDevice`: Modbus register/coil devices (TCP or RTU)
* `EtherNetIPDevice`: EtherNet/IP and CIP devices, via `instro.ethernetip` (install with `instro[ethernetip]`)

### Drivers

These are the vendor/model-specific drivers available out of the box.

* `InstroPSU`
  * B\&K Precision
  * Keysight
  * Siglent
  * Rigol
  * TDK Lambda
  * Simulated (no hardware required)
* `InstroDAQ`
  * National Instruments (NI)
  * LabJack T-Series
  * Measurement Computing (MCC)
  * Keysight 34980
* `InstroELoad`
  * B\&K Precision 85xx Series
* `I2CInterface`
  * Total Phase Aardvark
* `InstroDMM`
  * Keithley 2400
  * Keithley 2750 (unstable)
  * Agilent/HP/Keysight 34401A
  * Simulated (no hardware required)
* `InstroScope`
  * Keysight 1200X
  * Tektronix 2-Series
  * Siglent SDS1000X-E

### Publishers

These are the publishers available out of the box.

* `NominalCorePublisher`: sends data to a Nominal Core dataset
* `NominalConnectPublisher`: sends data to a Nominal Connect client
* `FilePublisher`: writes data to a local file in Avro, CSV, or JSON Lines

`BasicBufferedPublisher`, `QueuedPublisher`, and `SharedPublisher` wrap another publisher to add batching, background delivery, or explicit shared ownership. See [Publishers](/instrumentation/publishers) for configuration and examples.