# Oscilloscope (Scope)

> Using InstroScope for SCPI-based oscilloscopes

# InstroScope

`InstroScope` is a hardware abstraction layer (HAL) that provides a unified interface for SCPI-based oscilloscopes. The category class defines the vendor-independent API (`set_vertical_scale`, `fetch_waveform`, `measure`, `set_trigger_level`, …). A vendor-specific driver translates those calls into vendor commands.

## Supported Vendors

* **Keysight**: InfiniiVision 1200 X-Series via SCPI/VISA (`Keysight1200X`)
* **Siglent**: SDS1000X-E series via SCPI/VISA (`SiglentSDS1000XE`)
* **Tektronix**: 2 Series MSO via SCPI/VISA (`Tektronix2SeriesMSO`)

If your vendor or model is not listed, see [Custom Driver Development](#custom-driver-development) below.

## Key Concepts

### Driver Composition

An `InstroScope` is built from a concrete driver:

```
InstroScope("name", driver=Keysight1200X("<visa_resource>"), num_channels=4)
```

* **`Keysight1200X`** owns the connection setup and vendor-specific command mapping.
* **`InstroScope`** owns the category-level workflow: configuration tracking, acquisition control, measurements, waveform fetches, publishers, the background daemon.

### Lifecycle

1. **Construct**: instantiate the vendor driver and pass it to `InstroScope`.
2. **`open()`**: establish the VISA connection.
3. **Configure**: set vertical (per channel), horizontal, acquisition, and trigger settings.
4. **Acquire**: arm a single-shot with `single()`, or free-run with `run()`.
5. **Read**: fetch a waveform with `fetch_waveform()` or take a built-in measurement with `measure()`.
6. **`close()`**: disconnect from hardware.

### Acquisition Control vs. the Background Daemon

`InstroScope` has two independent start/stop concepts:

* **Acquisition control** drives the instrument: `run()`, `single()`, and `stop_acquisition()`. These map to the front-panel Run, Single, and Stop keys. After `single()`, both `fetch_waveform()` and `measure()` block up to their `timeout` for the trigger to fire, then read. They raise `TimeoutError` if it does not.
* **The background daemon** drives polling on the host: `start()` and `stop()` (inherited from `Instrument`) periodically call the methods you register and stream their results to publishers.

### Configuration Tracking

`InstroScope` tracks vertical, horizontal, acquisition, and trigger state locally as you issue commands. Call `sync_configuration()` after `open()` (or after `load_settings()`) to bulk-query the instrument and overwrite the tracked state.

<Note>
  `sync_configuration()` does not bulk-query trigger source, type, level, slope, or mode. Not all scopes expose those through a simple query, so set them explicitly to populate the tracked state.
</Note>

### Measurements

`measure(measurement_type, channel)` reads a built-in measurement: `VPP`, `VMAX`, `VMIN`, `VAVG`, `VRMS`, `FREQUENCY`, `PERIOD`, or `DUTY_CYCLE`. It returns `NaN` when the scope has no valid result (no acquisition yet, channel off). `fetch_waveform(channel)` returns a `Measurement` whose timestamps are relative to the trigger point (negative values are pre-trigger), with voltages already scaled through the configured probe attenuation.

## Creating an InstroScope Instance

```python theme={null}
from instro.scope.drivers import Keysight1200X
from instro.scope import InstroScope

scope = InstroScope(
    name="myScope",
    driver=Keysight1200X("<visa_resource>"),
    num_channels=4,
)
```

### Parameters

* **`name`**: A name for this scope instance. Used as a prefix for channel names when publishing.
* **`driver`**: A concrete `ScopeDriverBase` instance configured with the connection details for that model.
* **`num_channels`**: Number of analog-input channels on the oscilloscope.
* **`publishers`**: Optional list of publishers to attach.
* **`**kwargs`**: Additional keyword arguments become default tags when using a publisher that supports tags (like `NominalCorePublisher`). Pass [`legacy_naming=True`](/instrumentation/library#backwards-compatible-channel-naming-legacy_naming) here to publish pre-v1.0 channel names.

### Choosing a Driver

Choose the driver that matches the model, then pass it the connection settings. Use `Keysight1200X`, `SiglentSDS1000XE`, or `Tektronix2SeriesMSO`. Each accepts a VISA resource string or a `VisaConfig`.

To inspect a VISA instrument's identity before choosing a driver:

```python theme={null}
from instro.lib.transports import VisaDriver

visa = VisaDriver("<visa_resource>")
try:
    visa.open()
    print(visa.query("*IDN?"))
finally:
    visa.close()
```

## Examples

All measurement methods return [`Measurement`](/instrumentation/library#measurement) objects. This is common amongst all `Instrument` objects.

### Basic Usage

```python theme={null}
from instro.lib.publishers import NominalCorePublisher
from instro.scope import (
    AcquisitionMode,
    Coupling,
    InstroScope,
    ScopeMeasurementType,
    TriggerMode,
    TriggerSlope,
    TriggerType,
)
from instro.scope.drivers import Keysight1200X

VISA_RESOURCE = "<visa_resource>"
DATASET_RID = "<your dataset here>"

scope = InstroScope(
    name="myScope",
    driver=Keysight1200X(VISA_RESOURCE),
    num_channels=4,
)
scope.add_publisher(NominalCorePublisher(dataset_rid=DATASET_RID))

scope.open()

# Configure channel 1
scope.set_coupling(Coupling.DC, channel=1)
scope.set_probe_attenuation(1.0, channel=1)
scope.set_vertical_scale(1.0, channel=1)  # 1 V/div
scope.set_vertical_offset(0.0, channel=1)

# Configure timebase and acquisition
scope.set_horizontal_scale(0.01)  # 10 ms/div
scope.set_acquisition_mode(AcquisitionMode.NORMAL)

# Configure the trigger
scope.set_trigger_source(channel=1)
scope.set_trigger_type(TriggerType.EDGE)
scope.set_trigger_slope(TriggerSlope.RISING)
scope.set_trigger_level(0.0)
scope.set_trigger_mode(TriggerMode.NORMAL)

# Arm a single-shot, then fetch and measure (both block for the trigger)
scope.single()
waveform = scope.fetch_waveform(channel=1)
vpp = scope.measure(ScopeMeasurementType.VPP, channel=1)
freq = scope.measure(ScopeMeasurementType.FREQUENCY, channel=1)
print(f"Vpp: {vpp.latest}, Frequency: {freq.latest}")

scope.save_screenshot("capture.png")  # Saves to the host
scope.close()
```

<Note>
  **Important Note about Publishers**

  Data is published as a direct result of an instrument method being called. Calling `measure()` reads the value from the instrument and causes all attached publishers to publish it automatically.
</Note>

### Background Daemon for Continuous Monitoring

Register the measurements to poll, free-run the instrument with `run()`, then `start()` the daemon.

```python theme={null}
from instro.lib.publishers import NominalCorePublisher
from instro.scope import AcquisitionMode, Coupling, InstroScope, ScopeMeasurementType
from instro.scope import TriggerMode, TriggerSlope, TriggerType
from instro.scope.drivers import Keysight1200X

scope = InstroScope(
    name="myScope",
    driver=Keysight1200X("<visa_resource>"),
    num_channels=2,
)
scope.add_publisher(NominalCorePublisher(dataset_rid="<your dataset here>"))
scope.background_interval = 0.5  # Poll every 500ms (default is 1 second)

scope.open()

# Configure channel 1, timebase, acquisition, and trigger
scope.set_coupling(Coupling.DC, channel=1)
scope.set_vertical_scale(1.0, channel=1)  # 1 V/div
scope.set_horizontal_scale(0.01)  # 10 ms/div
scope.set_acquisition_mode(AcquisitionMode.NORMAL)
scope.set_trigger_source(channel=1)
scope.set_trigger_type(TriggerType.EDGE)
scope.set_trigger_slope(TriggerSlope.RISING)
scope.set_trigger_level(0.0)
scope.set_trigger_mode(TriggerMode.NORMAL)

# Register the measurements the daemon should poll
scope.add_background_daemon_function(scope.measure, ScopeMeasurementType.VRMS, channel=1)
scope.add_background_daemon_function(scope.measure, ScopeMeasurementType.VPP, channel=1)

# Free-run the instrument, then start the daemon
scope.run()
scope.start()

while True:
    try:
        vrms = scope.get_channel("myScope.ch1.vrms", length=1, wait_for_new_samples=True)
        vpp = scope.get_channel("myScope.ch1.vpp", length=1)
        print(f"Vrms: {vrms.latest}, Vpp: {vpp.latest}")
    except KeyboardInterrupt:
        break

scope.stop()  # Stop the daemon
scope.stop_acquisition()  # Stop the instrument
scope.close()
```

<Note>
  **Scope Background Daemon**

  `InstroScope` registers no default daemon functions. Register the measurements with `add_background_daemon_function()` before `start()`, or use `define_background_daemon()` to replace the registered set. The default polling interval is 1 second, configurable via `background_interval`.
</Note>

See [Two ways to get data](/instrumentation/overview#two-ways-to-get-data) for more on background fetching.

## Published channels

Every call produces a channel keyed under `{name}.{descriptor}`, where `{name}` is the constructor argument and `{descriptor}` is the row below. Substitute `{N}` with the channel number and `{type}` with the lowercased measurement type (e.g. `vpp`). Pass [`legacy_naming=True`](/instrumentation/library#backwards-compatible-channel-naming-legacy_naming) to the constructor for the pre-v1.0 names.

| Method                                      | Descriptor                        | Type      |
| ------------------------------------------- | --------------------------------- | --------- |
| `set_vertical_scale(channel=N)`             | `ch{N}.vscale.cmd`                | command   |
| `get_vertical_scale(channel=N)`             | `ch{N}.vscale`                    | telemetry |
| `set_vertical_offset(channel=N)`            | `ch{N}.voffset.cmd`               | command   |
| `get_vertical_offset(channel=N)`            | `ch{N}.voffset`                   | telemetry |
| `set_coupling(channel=N)`                   | `ch{N}.coupling.cmd`              | command   |
| `get_coupling(channel=N)`                   | `ch{N}.coupling.cmd`              | command   |
| `set_probe_attenuation(channel=N)`          | `ch{N}.probe_attenuation.cmd`     | command   |
| `get_probe_attenuation(channel=N)`          | `ch{N}.probe_attenuation`         | telemetry |
| `set_horizontal_scale()`                    | `hscale.cmd`                      | command   |
| `get_horizontal_scale()`                    | `hscale`                          | telemetry |
| `get_sample_rate()`                         | `sample_rate`                     | telemetry |
| `set_acquisition_mode()`                    | `acquisition_mode.cmd`            | command   |
| `get_acquisition_mode()`                    | `acquisition_mode.cmd`            | command   |
| `set_average_count()`                       | `average_count.cmd`               | command   |
| `get_average_count()`                       | `average_count`                   | telemetry |
| `run()` / `stop_acquisition()` / `single()` | `acquisition_control.cmd`         | command   |
| `get_acquisition_state()`                   | `acquisition_state.cmd`           | command   |
| `fetch_waveform(channel=N)`                 | `ch{N}.waveform`                  | telemetry |
| `measure(type, channel=N)`                  | `ch{N}.{type}` (e.g. `ch{N}.vpp`) | telemetry |
| `set_trigger_source()`                      | `trigger_source.cmd`              | command   |
| `set_trigger_type()`                        | `trigger_type.cmd`                | command   |
| `set_trigger_level()`                       | `trigger_level.cmd`               | command   |
| `set_trigger_slope()`                       | `trigger_slope.cmd`               | command   |
| `set_trigger_mode()`                        | `trigger_mode.cmd`                | command   |
| `force_trigger()`                           | `trigger_control.cmd`             | command   |
| `get_trigger_status()`                      | `trigger_status.cmd`              | command   |
| `save_screenshot()`                         | `screenshot.cmd`                  | command   |
| `save_settings()`                           | `save_settings.cmd`               | command   |
| `load_settings()`                           | `load_settings.cmd`               | command   |

## Method Reference

| Method                                                               | Purpose                                                                              |
| -------------------------------------------------------------------- | ------------------------------------------------------------------------------------ |
| `InstroScope(name, driver, num_channels, publishers=None, **kwargs)` | Construct an InstroScope with a vendor driver                                        |
| `open()`                                                             | Establish the VISA connection to the scope                                           |
| `close()`                                                            | Disconnect from scope and close all publishers                                       |
| `sync_configuration()`                                               | Bulk-query the instrument and overwrite the tracked configuration                    |
| `set_vertical_scale(volts_per_div, channel=N)`                       | Set the vertical scale in volts/div                                                  |
| `get_vertical_scale(channel=N)`                                      | Read the vertical scale in volts/div                                                 |
| `set_vertical_offset(offset, channel=N)`                             | Set the vertical offset in volts                                                     |
| `get_vertical_offset(channel=N)`                                     | Read the vertical offset in volts                                                    |
| `set_coupling(coupling, channel=N)`                                  | Set AC/DC input coupling                                                             |
| `get_coupling(channel=N)`                                            | Read the input coupling                                                              |
| `set_probe_attenuation(factor, channel=N)`                           | Set the probe attenuation ratio (e.g. 1, 10, 100)                                    |
| `get_probe_attenuation(channel=N)`                                   | Read the probe attenuation ratio                                                     |
| `set_horizontal_scale(seconds_per_div)`                              | Set the timebase in seconds/div (applies to all channels)                            |
| `get_horizontal_scale()`                                             | Read the timebase in seconds/div                                                     |
| `get_sample_rate()`                                                  | Read the effective sample rate in samples/second                                     |
| `set_acquisition_mode(mode)`                                         | Set the acquisition mode (NORMAL, AVERAGE, HIGH\_RESOLUTION, PEAK\_DETECT, ENVELOPE) |
| `get_acquisition_mode()`                                             | Read the acquisition mode                                                            |
| `set_average_count(count)`                                           | Set the waveforms-to-average count (used in AVERAGE mode)                            |
| `get_average_count()`                                                | Read the waveforms-to-average count                                                  |
| `run()`                                                              | Start continuous (free-running) acquisition                                          |
| `stop_acquisition()`                                                 | Stop acquisition, leaving captured data intact                                       |
| `single()`                                                           | Arm a single-shot acquisition                                                        |
| `get_acquisition_state()`                                            | Read the acquisition run state (RUNNING / STOPPED)                                   |
| `fetch_waveform(channel=N, timeout=5.0)`                             | Fetch the most recently acquired waveform                                            |
| `measure(measurement_type, channel=1, timeout=5.0)`                  | Take a built-in measurement                                                          |
| `set_trigger_source(channel)`                                        | Set the trigger source channel                                                       |
| `set_trigger_type(trigger_type)`                                     | Set the trigger type (EDGE, PULSE)                                                   |
| `set_trigger_level(level)`                                           | Set the trigger threshold in volts                                                   |
| `set_trigger_slope(slope)`                                           | Set the trigger edge slope (RISING, FALLING, EITHER)                                 |
| `set_trigger_mode(mode)`                                             | Set the trigger sweep mode (AUTO, NORMAL)                                            |
| `force_trigger()`                                                    | Force a trigger event immediately                                                    |
| `get_trigger_status()`                                               | Read the trigger status (ARMED, READY, TRIGGERED, …)                                 |
| `save_screenshot(filepath, to_instrument=False)`                     | Capture a screenshot to the host or the scope's filesystem                           |
| `save_settings(name, to_instrument=False)`                           | Save the current scope setup                                                         |
| `load_settings(name, from_instrument=False)`                         | Recall a scope setup (invalidates tracked configuration)                             |
| `start()`                                                            | Begin the background telemetry daemon                                                |
| `stop()`                                                             | End the background telemetry daemon                                                  |

***

# Custom Driver Development

This section is for developers implementing `InstroScope` support for oscilloscopes that aren't supported out of the box.

A scope driver subclasses `ScopeDriverBase` and owns its transport. Its responsibilities:

1. **Expose a protocol-native constructor**: accept a `visa_resource` string or `VisaConfig`.
2. **Own transport setup**: create and store the transport internally. Do not require callers to pass a `VisaDriver`.
3. **Own lifecycle**: implement `open()` and `close()`.
4. **Map commands**: translate each abstract method into vendor commands.
5. **Parse responses**: convert responses to the expected types (`float`, enums, `WaveformData`).
6. **Drain the error queue**: implement `check_errors()`. `InstroScope` calls it between setup commands and blocking queries, so a pending syntax error raises instead of hanging a data query.

Channels are 1-indexed analog input numbers throughout.

## ScopeDriverBase Interface

All scope drivers subclass `ScopeDriverBase` and implement these abstract methods:

```python theme={null}
def open(self) -> None: ...
def close(self) -> None: ...
def check_errors(self) -> None: ...

# Channel vertical settings
def set_vertical_scale(self, volts_per_div: float, channel: int) -> None: ...
def get_vertical_scale(self, channel: int) -> float: ...
def set_vertical_offset(self, offset: float, channel: int) -> None: ...
def get_vertical_offset(self, channel: int) -> float: ...
def set_coupling(self, coupling: Coupling, channel: int) -> None: ...
def get_coupling(self, channel: int) -> Coupling: ...
def set_probe_attenuation(self, factor: float, channel: int) -> None: ...
def get_probe_attenuation(self, channel: int) -> float: ...

# Horizontal (timebase) and sample rate
def set_horizontal_scale(self, seconds_per_div: float) -> None: ...
def get_horizontal_scale(self) -> float: ...
def get_sample_rate(self) -> float: ...

# Acquisition
def set_acquisition_mode(self, mode: AcquisitionMode) -> None: ...
def get_acquisition_mode(self) -> AcquisitionMode: ...
def set_average_count(self, count: int) -> None: ...
def get_average_count(self) -> int: ...
def run(self) -> None: ...
def stop(self) -> None: ...
def single(self) -> None: ...
def digitize(self, timeout: float) -> None: ...
def get_acquisition_state(self) -> AcquisitionState: ...

# Waveform data and measurements
def fetch_waveform(self, channel: int) -> WaveformData: ...
def measure(self, measurement_type: ScopeMeasurementType, channel: int) -> float: ...

# Trigger
def set_trigger_source(self, channel: int) -> None: ...
def set_trigger_type(self, trigger_type: TriggerType) -> None: ...
def set_trigger_level(self, level: float) -> None: ...
def set_trigger_slope(self, slope: TriggerSlope) -> None: ...
def set_trigger_mode(self, mode: TriggerMode) -> None: ...
def force_trigger(self) -> None: ...
def get_trigger_status(self) -> TriggerStatus: ...

# File operations
def save_screenshot(self, filepath: str, to_instrument: bool = False) -> bytes: ...
def save_settings(self, name: str, to_instrument: bool = False) -> bytes: ...
def load_settings(self, name: str, from_instrument: bool = False) -> None: ...
```

`setup_measurement(measurement_type, channel)` is an optional override (default no-op). Implement it for instruments that compute measurements during acquisition (e.g. Tektronix), where the measurement slot must exist at trigger time. Raise `NotImplementedError` for `AcquisitionMode` values the scope does not support (e.g. the Keysight 1200X has no `ENVELOPE` mode). See [Exceptions](/instrumentation/exceptions) for unsupported-feature handling.

For VISA-backed drivers, create a `VisaDriver` internally and use `self._visa.write(command)` and `self._visa.query(command)` for all I/O. `VisaDriver` owns the resource lock and serializes concurrent calls. See the [VisaDriver guide](/instrumentation/transports/visa) for the full transport reference.

## Implementation Example: Keysight 1200 X-Series Driver

```python theme={null}
from __future__ import annotations

import math

from instro.lib.transports.visa import VisaConfig, VisaDriver
from instro.scope import ScopeDriverBase

# IEEE-488.2 sentinel returned when a measurement has no valid result.
_VENDOR_INVALID_MEASUREMENT = 9.91e37


class Keysight1200X(ScopeDriverBase):
    """SCPI driver for Keysight InfiniiVision 1200 X-Series oscilloscopes."""

    def __init__(self, visa_resource: str | VisaConfig) -> None:
        self._visa = VisaDriver(visa_resource)
        self._trigger_source: int | None = None

    def open(self) -> None:
        self._visa.open()

    def close(self) -> None:
        self._visa.close()

    def check_errors(self) -> None:
        while True:
            resp = self._visa.query(":SYSTem:ERRor?")
            parts = resp.split(",", 1)
            code = int(parts[0])
            if code == 0:
                return
            msg = parts[1].strip().strip('"') if len(parts) > 1 else "Unknown error"
            raise RuntimeError(f"Keysight SCPI error {code}: {msg}")

    def set_vertical_scale(self, volts_per_div: float, channel: int) -> None:
        self._visa.write(f":CHANnel{channel}:SCALe {volts_per_div}")

    def get_vertical_scale(self, channel: int) -> float:
        return float(self._visa.query(f":CHANnel{channel}:SCALe?"))

    # ...remaining channel, timebase, acquisition, trigger, and file methods...
```

<Tip>
  **Vendor SCPI Variations**

  Scope vendors differ in SCPI command sets, error-query forms, and waveform-preamble formats. The Keysight 1200X computes measurements on demand, while the Tektronix 2 Series requires measurement slots installed before the trigger fires (`setup_measurement`). Always consult your oscilloscope's programming manual.
</Tip>

## Using a Custom Driver

Construct `InstroScope` with your own driver instance:

```python theme={null}
from instro.scope import InstroScope, ScopeDriverBase
from instro.lib.transports import VisaDriver


class MyCustomScopeDriver(ScopeDriverBase):
    """Custom driver for my lab's proprietary oscilloscope."""

    def __init__(self, visa_resource: str) -> None:
        self._visa = VisaDriver(visa_resource)

    def open(self) -> None:
        self._visa.open()

    def close(self) -> None:
        self._visa.close()

    def check_errors(self) -> None:
        err = self._visa.query("SYST:ERR?")
        if not err.startswith("0"):
            raise RuntimeError(f"Scope error: {err}")

    def set_vertical_scale(self, volts_per_div: float, channel: int) -> None:
        self._visa.write(f"CH{channel}:SCALE {volts_per_div}")

    # ... implement the other abstract methods ...


scope = InstroScope(
    name="labScope",
    driver=MyCustomScopeDriver(visa_resource="<visa_resource>"),
    num_channels=4,
)
scope.open()
scope.set_vertical_scale(1.0, channel=1)
scope.close()
```